Mounting onto the manifold
- Remove the existing isolating cap
- Position the actuator onto the port value
- Tighten the ring nut by hand- do NOT use a spanner or similar tool.
- Connect the electrical wiring to complete.
Function of Normally Closed Version (NC)
- When applying the operating voltage, the expansion system of the actuator will be heated. After passing the dead time a uniform procedure will follow.
- When the voltage supply is cut off, the actuator will automatically close after passing the dead time due to calling of the expansion system.
Note: in case of any functional testing, be aware of the dead time behaviour and take this into consideration. The opening and closing ties will depend upon the ambient temperature.
Technical Data | |
---|---|
Operating voltage | 230v/AC, 25v/DC (+10%/-15%) |
Frequency | 0 up to 60Hz |
Power consumption | 3w (VA) in continuous operation |
Starting phase | 90w (VA) |
Version | NC |
Closing and opening times | approx. 3min |
Overvoltage protection | Varistor |
Approvals | CE |
Type of protection | acc. To EN 60529 |
Connecting cable | standard type 1m fixed; 2*0.75 mm² |
Ambient temperature | 0°c up to 50°c during operation |
Medium temperature | max. 100°c |
Storage temperature | -20°c up to +70°c |